AVB

Second-degree AVB, Type I

Sat, 02/16/2013 - 19:52 -- Dawn

This 67 year old man is noted to have a slightly irregular pulse.  At the beginning of this ECG, he appears to be in NSR with a first-degree AV block.  Twice, P waves are non-conducted.  Careful measurement of the P to P interval shows that it is regular, there are no PACs noted.  The PR interval changes very subtly by lengthening just before the non-conducted P waves.  A hint when non-conducted P waves are noted, first check for non-conducted PACs.  If the sinus rhythm is regular, check the PR interval before the non-conducted beat, and the PR interval immediately after the non-conducted beat.  You will see the PRI preceding the non-conducted P is longer than the PRI after the NCP.

Wenckebach conduction is caused by RP/PR reciprocity.  In other words, the shorter the RP interval, the longer the PR interval.  So, as the PRI lengthens, the QRS "moves" to the right, eventually causing the next regular sinus P wave to fall into the refractory period and fail to conduct.  This results in a pause, or a long RP interval, which shortens the next PRI. 

 If you or your students would like to review AV Blocks, go to this LINK for Dr. Grauer's excellent, FREE, self-directed tutorial.

For a slightly more advanced discussion of RP/PR reciprocity, see Jason's Blog.

 

Third-degree AV Block and Junctional Escape Rhythm With Right Bundle Branch Block and Prolonged QTc Interval

Sat, 01/26/2013 - 14:48 -- Dawn

This ECG is from a 70 year old woman for which we have, unfortunately, no clinical information.  It shows a sinus rhythm with a rate of about 72 bpm (NSR) with AV dissociation caused by third-degree heart block.  The escape rhythm is junctional at a rate of 38 bpm.  There appears to be a right bundle branch block, based on the QRS duration of 132 ms, and a wide S wave in Leads I and V6.  The precordial leads do not show the usual RBBB pattern of rSR' in V1 and V2, and the r wave progression is poor (non-existent).  This is felt to be due to poor lead placement (a good teaching point).  Of interest, the ECG machine has reported a "severe right axis deviation" based on the tall upright R wave in aVR and the deep S in avF.  In RBBB, the first part of the QRS represents left ventricular depolarization, and the terminal wave represents the delayed right ventricle.  In effect, the two ventricles have their own electrical axes, which we can see because the ventricles are not depolarizing simultaneously.  The axis of the LV appears to be normal in this tracing.

In addition to the above, this patient has a very prolonged QT interval.  The QT is longer in bradycardic rhythms, but when corrected to a standard of 60 bpm (QTc), this patient's QT interval is still prolonged at QTc: 552 ms.  Without clinical data, we cannot speculate  as to why this patient's QTc is prolonged, but it can be a very dangerous situation.  Follow the links for more information on QT prolongation and Torsades de Pointes and Long QT Syndrome.

As always, we welcome comments from our members adding insight to this interesting ECG, and also questions you would like to ask our Guru members.

Inferior Wall M.I. With Right Ventricular M.I.

Sat, 01/12/2013 - 21:49 -- Dawn

This week's ECG of the Week is from an elderly woman who suffered an acute occlusion of the right coronary artery.  The ECG clearly shows ST elevation in leads II, III, and aVF, indicating inferior wall injury.  In this case, this ECG was obtained in the field by paramedics, and was the second ECG done on this patient. For this tracing, the paramedics obtained V3 and V4 on the right side to better view the right ventricle. V3 and V4 right clearly show ST elevation as well, indicating RVMI.  The slight coving and elevation observable in V1 is also an indication of RV involvement, and the ST depression in V2 indicates posterior wall injury.  All of this results from a proximal lesion of the RCA in this patient.  Such a lesion carries a high morbidity and mortality.

Taking the time to obtain a right ventricular lead is controversial in some settings.  Some believe the patient's hemodynamic condition should be treated, regardless of the presence or absence of ST elevation in right chest leads.  Others find it very helpful to know that the right ventricle is affected.  In this case, paramedics in this community have a protocol to avoid the use of nitroglycerine in RVMI patients, even when the BP is adequate.  So, for them, it is important to have the information gathered from V Right leads.

The rhythm here is interesting, as well, and not at all uncommon for IWMI patients.  The baseline artifact makes it a bit difficult to march out all the P waves, but it appears they are sinus P waves that are slightly irregular at a rate of 52 to 54.  The PR intervals appear to be progressively prolonging, but there is no "grouped beating" observable on this short strip.  A lack of a concurrent Lead II rhythm strip also makes it difficult to determine the rhythm, as Lead II does have very visible P waves, and would be helpful.  The regularity of the narrow complex bradycardia points to a junctional escape rhythm, which would make this a third-degree AVB at the AV node level, which is very common with IWMI.  What do you think?

This month's strip from Jason Roediger's ECG Challenge blogpost is a nice complement to the strip presented here.  His is much clearer, and has a Lead II rhythm strip.  Do you think these ECGs show the same rhythm, or two different rhythms?

For an excellent discussion of "AV Dissociation" vs. "AV Block", go to Christopher Watford's Ask the Expert post.  Thanks very much to ECG Guru Sebastian Garay for this interesting ECG.

Third-degree AV Block

Wed, 08/22/2012 - 18:37 -- Dawn

This 84-year-old man called 911 because he felt dizzy and fell.  He was not injured in the fall, but the paramedics noted a slow pulse. He denied significant medical history. The initial ECG showed sinus rhythm at about 80 bpm and AV dissociation with an apparent acellerated idioventricular rhythm at about 40 bpm.  Less than one minute later, he has developed a complete heart block with an idioventricular escape rhythm less than 30 bpm.  The escape rhythm speeds slightly toward the end of the strip.  He retained stable vital signs and adequate perfusion during transport.  It is presumed that he was scheduled for an implanted pacemaker.  It is interesting to note the machine's interpretation, and it reminds us to always interpret the ECG ourselves.   Thanks to ECG Guru member, Sebmedic, for his contribution of this ECG. 

Subscribe to RSS - AVB